Year 2019 / Volume 111 / Number 3
Original
Usefulness of bioelectrical impedance analysis for monitoring patients with refractory ascites

223-227

DOI: 10.17235/reed.2018.5634/2018

Guillermo Ontanilla-Clavijo, Javier Ampuero, Samuel Borreguero, Javier Rosell, Manuel Romero-Gómez,

Abstract
Background: bioelectrical impedance analysis is a technique for the determination of the hydropic component. The hydropic component, determined by blood volume, could be a reflection of the hemodynamic situation. This study aimed to evaluate the usefulness of peripheral bioelectrical impedance analysis (BIA) for the prediction of hemodynamic changes in large-volume paracentesis and prognosis. Methods: this was a proof-of-concept prospective study of 14 patients with liver cirrhosis and refractory ascites. Peripheral bioimpedance was measured three times using a portable device, IVOL®, before and after large-volume paracentesis, at different frequencies (5, 10, 20, 50, 100 and 200 kHz). Consequently, resistance, reactance and phase angle were obtained, both pre- and post-paracentesis (the difference between them was defined as Δ). Results: the mean age of patients was 62.2 ± 9.6 years, the Child-Pugh was 8.4 ± 1.3 and the MELD score was 15.2 ± 3.9. A direct correlation between the extraction of ascitic fluid and Δresistance (10 kHz [r = 0.722; n = 12; p = 0.008], 20 kHz [r = 0.658; n = 12; p = 0.020] and 50 kHz [r = 0.519; n = 14; p = 0.057]) was observed. The presence of edema was related to lower values of both pre-paracentesis resistance (10 Hz [23.9  8 vs 32.2  4; p = 0.043]) and phase angle (5 kHz [-1.9 2.8 vs 5.9  7.3; p = 0.032]). Pre-paracentesis phase angle was directly correlated with the decline in blood pressure after paracentesis at lower frequencies (5 kHz [r = 0.694; n = 13; p = 0.008] and 10 kHz [r = 0.661; n = 13; p = 0.014]). Lower frequencies of Δphase-angle impacted on patient prognosis (5 kHz [-8.6 ± 5 vs -2.5 ± 2.7; p = 0.021]), patients with Δphase-angle 5 kHz > -4 had a higher rate of mortality (83.3% [5/6] vs 0% [0/6]; logRank 7.306, p = 0.007). Δresistance values were associated with overt HE at six months (10 kHz [4.9  2.5 vs -0.4  4.7; p = 0.046]). Conclusions: in conclusion, a significant correlation between peripheral impedance and hemodynamic changes was found. Impedance was also significantly related to prognosis and overt hepatic encephalopathy.
Share Button
New comment
Comments
No comments for this article
Related articles

Editorial

Treatment of portal vein thrombosis in cirrhosis patients

DOI: 10.17235/reed.2023.9800/2023

Editorial

AKI-HRS, more than a name change for type-1 hepatorenal syndrome

DOI: 10.17235/reed.2023.9677/2023

Editorial

New actors come into play against hepatitis delta

DOI: 10.17235/reed.2022.9050/2022

Letter

Hemoperitoneum due to rupture of intra-abdominal varices

DOI: 10.17235/reed.2022.8937/2022

Letter

Cirrhotic pattern in advanced hepatic sarcoidosis

DOI: 10.17235/reed.2021.8446/2021

Digestive Diseases Image

Giant cystic hepatocarcinoma in the absence of cirrhosis

DOI: 10.17235/reed.2021.8313/2021

Review

Physical frailty in liver transplantation

DOI: 10.17235/reed.2020.7448/2020

Letter

Hemorrhagic complications following paracentesis

DOI: 10.17235/reed.2020.6914/2020

Case Report

Using octreotide for refractory ascites after liver transplantation

DOI: 10.17235/reed.2019.6316/2019

Review

Risk stratification and treatment of primary biliary cholangitis

DOI: 10.17235/reed.2018.5662/2018

Citation tools
Ontanilla-Clavijo G, Ampuero J, Borreguero S, Rosell J, Romero-Gómez M. Usefulness of bioelectrical impedance analysis for monitoring patients with refractory ascites. 5634/2018


Download to a citation manager

Download the citation for this article by clicking on one of the following citation managers:

Metrics
This article has received 1206 visits.
This article has been downloaded 192 times.

Statistics from Dimensions


Statistics from Plum Analytics

Publication history

Received: 31/03/2018

Accepted: 20/10/2018

Online First: 04/12/2018

Published: 04/03/2019

Article revision time: 175 days

Article Online First time: 248 days

Article editing time: 338 days


Share
This article has been rated by 1 readers.
Reader rating:
Valora este artículo:




Asociación Española de Ecografía Digestiva Sociedad Española de Endoscopia Digestiva Sociedad Española de Patología Digestiva
The Spanish Journal of Gastroenterology is the official organ of the Sociedad Española de Patología Digestiva, the Sociedad Española de Endoscopia Digestiva and the Asociación Española de Ecografía Digestiva
Cookie policy Privacy Policy Legal Notice © Copyright 2023 y Creative Commons. The Spanish Journal of Gastroenterology