Dear Editor, A 75-year-old woman living in a nursing home presented with a 24-hour history of abdominal cramping and vomiting. Medical history was remarkable for dementia and a percutaneous endoscopic gastrostomy (PEG) was performed 3 years earlier. The day before the admission the feeding tube was accidentally pulled out and a Foley catheter was placed in order to avoid stoma closure. On physical examination, there was extravasation of the gastric content through the stoma. The base of the “Y” of the Foley catheter was introduced in the gastric stoma and a pulling sensation was felt when it was mobilized. The remainder abdominal examination was unremarkable. On esophagogastroduodenoscopy the Foley catheter was identified passing the pylorus and pulling duodenal bulb towards the antrum (Figure 1). Advancing the scope through the duodenum, the Foley balloon impacted in the duodenal apex was identified. There was no mucosal injury so the balloon was deflated and the catheter removed. A 14 Fr. Bard® PEG tube was latter placed to allow a reduction in the calibre of the stoma. Gastric outlet obstruction is an unusual adverse event of PEG tubes. In adults it is usually related to Foley catheters use as peristalsis can pull the balloon into the duodenum in the absence of an external bumper. A clinical picture of abdominal cramping, vomiting and resistance to the attempt of percutaneous reposition should raise the suspicion of gastrostomy tube migration through the pylorus. Foley catheters are easily available and some may use it to prevent gastrostomy closure after accidentally PEG tube extraction. We have performed more than 800 PEG and assisted several cases of gastric outlet obstruction and even stoma damage in this setting. This case emphasises the importance of receiving an early PEG tube with external bumper replacement to prevent this adverse event.
Share Button
Nuevo comentario
Comentarios
No hay comentarios para este artículo.
Bibliografía
1. Schrag SP, Sharma R, Jaik NP, et al. Complications related to percutaneous endoscopic gastrostomy (PEG) tubes. A comprehensive clinical review. J Gastrointestin Liver Dis. 2007;16:407-18.
2. McGovern R, Barkin JS, Goldberg RI, et al. Duodenal obstruction: a complication of percutaneous endoscopic gastrostomy tube migration. Am J Gastroenterol. 1990;85:1037-8.
3. Nunes A, Santos C, Fonseca J. [Gastric outlet obstruction in a patient with percutaneous gastrostomy]. Rev Gastroenterol Mex. 2014;79:56-7.
4. Pinto Marques P, Fonseca J. Obstrução duodenal secundária a gastrostomia percutânea. GE -J Port Gastrenterol. 2006;13:157-8.
5. Kadakia SC, Cassaday M, Shaffer RT. Comparison of Foley catheter as a replacement gastrostomy tube with commercial replacement gastrostomy tube: a prospective randomized trial. Gastrointest Endosc. 1994;40(2 Pt 1):188-93.
Artículos relacionados

Imagen en Patología Digestiva

Abuso de cocaína crack como causa no descrita de obstrucción del vaciamiento gástrico

DOI: 10.17235/reed.2022.8438/2021

Imagen en Patología Digestiva

Pedunculated mucosa-associated lymphoid tissue (MALT) lymphoma causing gastric outlet obstruction

DOI: 10.17235/reed.2021.8204/2021

Carta al Editor

Manejo del neumoperitoneo no quirúrgico

DOI: 10.17235/reed.2016.4215/2016

Instrucciones para citar
Barosa R, Santos C, Fonseca J. Gastric outlet obstruction: An unusual adverse event of percutaneous endoscopic gastrostomy . 3936/2015


Descargar en un gestor de citas

Descargue la cita de este artículo haciendo clic en uno de los siguientes gestores de citas:

Métrica
Este artículo ha sido visitado 140 veces.
Este artículo ha sido descargado 52 veces.

Estadísticas de Dimensions


Estadísticas de Plum Analytics

Ficha Técnica

Recibido: 20/07/2015

Aceptado: 15/08/2015

Prepublicado: 23/11/2015

Publicado: 30/12/2015

Tiempo de revisión del artículo: 16 días

Tiempo de prepublicación: 126 días

Tiempo de edición del artículo: 163 días


Compartir
Este artículo aun no tiene valoraciones.
Valoración del lector:
Valora este artículo:




Asociación Española de Ecografía Digestiva Sociedad Española de Endoscopia Digestiva Sociedad Española de Patología Digestiva
La REED es el órgano oficial de la Sociedad Española de Patología Digestiva, la SociedadEspañola de Endoscopia Digestiva y la Asociación Española de Ecografía Digestiva
Política de cookies Política de Privacidad Aviso Legal © Copyright 2023 y Creative Commons. Revista Española de Enfermedades Digestivas