Resumen
The obesity pandemic is becoming one of the most prevalent diseases nowadays. There is a wide spectrum of treatment, ranging from hygienic-dietary measures to bariatric surgery. Endoscopic intragastric balloon placement is becoming increasingly more frequent, due to its technical simplicity, safety and short-term success(1). Although complications are rare some can be severe, so pre-endoscopic evaluation must be carried out carefully. A 43-year-old woman with a history of grade I obesity (BMI 32.7) had an Orbera® intragastric balloon implanted successfully. After the procedure she presented frequent nausea and vomiting, partially controlled with antiemetics. She attended the Emergency Department(ED) with a persistent emetic syndrome - oral intolerance and short-term loss of consciousness(syncope), for which she was admitted. Lab tests showed metabolic alkalosis with severe hypokalemia(K+ 1.8mmol/L), so fluid therapy was initiated for hydroelectrolytic replacement. During the patient’s stay in the ED, two episodes of polymorphic ventricular tachychardia “Torsades de Pointes” (PVT-TDP) occurred, leading to cardiac arrest and requiring electrical cardioversion to restore sinus rhythm, in addition to a temporary pacemaker placement. Telemetry showed a corrected QT interval of >500ms, compatible with Long QT Syndrome(LQTS). Once the patient was hemodynamically stabilized a gastroscopy was performed. The intragastric balloon located in the fundus was removed using an extraction kit, puncturing and aspirating 500ml of saline solution, and extracting the collapsed balloon without any complications. The patient achieved an adequate oral intake afterwards, and no recurrence of emetic episodes were noticed. Previous ECGs revealed a prolonged QT interval and a genetic study confirmed a congenital type 1 LQTS. Treatment was initiated with beta-blockers and a bicameral automatic defibrillator was implanted in order to prevent recurrences. Intragastric balloon placement is generally a safe procedure, serious complications present in 0.70% of cases(2). It is essential to have a proper pre-endoscopic evaluation, including patient's medical history and comorbidities. Episodes of PVT-TDP may present precipitated by certain medications (eg. metoclopramide) or hydroelectrolytic imbalances (eg, hypokalemia)(3). A standardized evaluation of ECG before intragastric balloon placement may be useful to prevent these rare but serious complications.
Share Button
Nuevo comentario
Comentarios
No hay comentarios para este artículo.
Bibliografía
1. Yorke E, Switzer NJ, Reso A, et al. Intragastric Balloon for Management of Severe Obesity: a Systematic Review. Obes Surg 2016; 26:2248.
2. Espinet Coll E, Del Pozo García AJ, Turró Arau R, et al. Spanish Intragastric Balloon Consensus Statement (SIBC): practical guidelines based on experience of over 20 000 cases. Rev Esp Enferm Dig. 2023 Jan;115(1):22-34.
Al-Khatib SM, Stevenson WG, Ackerman MJ, et al. 2017 AHA/ACC/HRS Guideline for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death: Executive Summary: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. J Am Coll Cardiol. 2018 Oct 2;72(14):1677-1749. doi: 10.1016/j.jacc.2017.10.053.
Instrucciones para citar
García-Calonge M, González-Sánchez M, Muíño-Domínguez D, Flórez-Díez P. Torsade de pointes secondary to long QT syndrome after intragastric balloon placement. A rare but severe complication. 9613/2023


Descargar en un gestor de citas

Descargue la cita de este artículo haciendo clic en uno de los siguientes gestores de citas:

Métrica
Este artículo ha sido visitado 385 veces.
Este artículo ha sido descargado 37 veces.

Estadísticas de Dimensions


Estadísticas de Plum Analytics

Ficha Técnica

Recibido: 20/03/2023

Aceptado: 14/04/2023

Prepublicado: 28/04/2023

Publicado: 04/03/2024

Tiempo de prepublicación: 39 días

Tiempo de edición del artículo: 350 días


Compartir
Este artículo aun no tiene valoraciones.
Valoración del lector:
Valora este artículo:




Asociación Española de Ecografía Digestiva Sociedad Española de Endoscopia Digestiva Sociedad Española de Patología Digestiva
La REED es el órgano oficial de la Sociedad Española de Patología Digestiva, la SociedadEspañola de Endoscopia Digestiva y la Asociación Española de Ecografía Digestiva
Política de cookies Política de Privacidad Aviso Legal © Copyright 2023 y Creative Commons. Revista Española de Enfermedades Digestivas