Año 2019 / Volumen 111 / Número 6
Editorial
Endoscopic ultrasound-guided drainage with lumen-apposing metal stents: a good safety profile also in the long term?

416-418

DOI: 10.17235/reed.2019.6348/2019

Enrique Pérez-Cuadrado Robles, Frédéric Prat, Pierre H. Deprez,

Resumen
Lumen-apposing metal stents (LAMSs) have been specifically designed for the endoscopic drainage of pancreatic fluid collections and walled-off necrosis. Lately, LAMS indications have expandedto other anastomoses, and these stents have proven to be effective in multiple situations. Safety data for this device are still limited, most studies to date being focused on intraoperative complications and not long-term issues. There are little data regarding the best timing for removal and the risks associated in leaving them in place for long duration. In addition, not all the procedure-related complications have the same clinical impact, and the settings in which LAMS have been used are heterogeneous, leading to different safety profiles and outcomes. A wide consensus on the definition of complications and a list of key performance measures for LAMS placement seems mandatory to allow for a robust assessment of their long-term outcomes.
Share Button
Nuevo comentario
Comentarios
No hay comentarios para este artículo.
Bibliografía
[1] Saumoy M, Yarber C, Kahaleh M. Novel Uses of Lumen-Apposing Metal Stents. Gastrointest Endosc Clin N Am. 2018; 28(2):197-205. doi: 10.1016/j.giec.2017.11.007.
[2] Larson B, Adler DG. Lumen-apposing metal stents for gastrointestinal luminal strictures: current use and future directions. Ann Gastroenterol. 2019; 32(2):141-146. doi: 10.20524/aog.2018.0337.
[3] Amateau SK, Lim CH, McDonald NM et al. EUS-Guided Endoscopic Gastrointestinal Anastomosis with Lumen-Apposing Metal Stent: Feasibility, Safety, and Efficacy. Obes Surg. 2018; 28(5):1445-1451. doi: 10.1007/s11695-018-3171-6.
[4] Arvanitakis M, Dumonceau JM, Albert J et al. Endoscopic management of acute necrotizing pancreatitis: European Society of Gastrointestinal Endoscopy (ESGE) evidence-based multidisciplinary guidelines. Endoscopy. 2018; 50(5):524-546. doi: 10.1055/a-0588-5365.
[5] Bang JY, Navaneethan U, Hasan MK et al. Non-superiority of lumen-apposing metal stents over plastic stents for drainage of walled-off necrosis in a randomised trial. Gut. 2018 Jun 1. pii: gutjnl-2017-315335. doi: 10.1136/gutjnl-2017-315335.
[6] Chen YI, Yang J, Friedland S et al. Lumen apposing metal stents are superior to plastic stents in pancreatic walled-off necrosis: a large international multicenter study. Endosc Int Open. 2019; 7(3):E347-E354. doi: 10.1055/a-0828-7630.
[7] Chen YI, Barkun AN, Adam V et al. Cost-effectiveness analysis comparing lumen-apposing metal stents with plastic stents in the management of pancreatic walled-off necrosis. Gastrointest Endosc. 2018; 88(2):267-276.e1. doi: 10.1016/j.gie.2018.03.021.
[8] Mussetto A, Fugazza A, Fuccio L et al. Current uses and outcomes of lumen-apposing metal stents. Ann Gastroenterol. 2018 ; 31(5):535-540. doi: 10.20524/aog.2018.0287.
[9] Hammad T, Khan MA, Alastal Y et al. Efficacy and Safety of Lumen-Apposing Metal Stents in Management of Pancreatic Fluid Collections: Are They Better Than Plastic Stents? A Systematic Review and Meta-Analysis. Dig Dis Sci. 2018; 63(2):289-301.
[10] Lang GD, Fritz C, Bhat T. EUS-guided drainage of peripancreatic fluid collections with lumen-apposing metal stents and plastic double-pigtail stents: comparison of efficacy and adverse event rates. Gastrointest Endosc. 2018; 87(1):150-157. doi: 10.1016/j.gie.2017.06.029.
[11] Bazaga Pérez de Rozas S, Yaiza Carbajo A, García-Alonso FJ et al. A retrospective, multicenter analysis of incidents associated with Axios lumen-apposing stents. Rev Esp Enferm Dig. 2019. In press.
[12] Amateau SK, Freeman ML. Avoidance, Recognition, and Management of Complications Associated with Lumen-Apposing Metal Stents. Gastrointest Endosc Clin N Am. 2018; 28(2):219-231. doi: 10.1016/j.giec.2017.11.009.
[13] Garcia-Alonso FJ, Sanchez-Ocana R, Peñas-Herrero I et al. Cumulative risks of stent migration and gastrointestinal bleeding in patients with lumen-apposing metal stents. Endoscopy. 2018; 50(4):386-395. doi: 10.1055/a-0581-9040.
[14] Petrone MC, Archibugi L, Forti E et al. Novel lumen-apposing metal stent for the drainage of pancreatic fluid collections: An Italian multicentre experience. United European Gastroenterol J. 2018; 6(9):1363-1371. doi: 10.1177/2050640618785078.
[15] Yang D, Perbtani YB, Mramba LK et al. Safety and rate of delayed adverse events with lumen-apposing metal stents (LAMS) for pancreatic fluid collections: a multicenter study. Endosc Int Open. 2018; 6(10):E1267-E1275. doi: 10.1055/a-0732-502.
[16] Siddiqui AA, Adler DG, Nieto J et al. EUS-guided drainage of peripancreatic fluid collections and necrosis by using a novel lumen-apposing stent: a large retrospective, multicenter U.S. experience (with videos). Gastrointest Endosc. 2016; 83(4):699-707. doi: 10.1016/j.gie.2015.10.020.
[17] Sevilla-Ribota S, Garcia-Alonso FJ, Sánchez-Ocaña R et al. Technical issues during EUS-guided placement of lumen apposing metal stents: definition and classification, incidence and risk factors, endoscopic management and effect on procedure outcomes. United European Gastroenterol J. 2018; 6 (Supplement 1).
Artículos relacionados

Carta

Acute cholecystitis treated by direct visualization endoscopy

DOI: 10.17235/reed.2023.9432/2022

Imagen en Patología Digestiva

Colangiopatía post-COVID: hallazgos ultrasonográficos y de CPRE

DOI: 10.17235/reed.2022.9218/2022

Carta

Angiosarcoma de aorta diagnosticado mediante ecoendoscopia

DOI: 10.17235/reed.2022.8879/2022

Imagen en Patología Digestiva

Linfoma pancreático durante el embarazo

DOI: 10.17235/reed.2022.8811/2022

Imagen en Patología Digestiva

When needles are not enough, forceps delivers!

DOI: 10.17235/reed.2022.8697/2022

Carta

Mesotelioma decidual maligno, ¿hasta dónde llegamos con USE?

DOI: 10.17235/reed.2021.8352/2021

Editorial

Guessing the future of endoscopic drainage of walled-off necrosis

DOI: 10.17235/reed.2020.7252/2020

Revisión

Management of pancreatic collections: an update

DOI: 10.17235/reed.2020.6814/2019

Imagen en Patología Digestiva

Endoscopic therapy in disconnected duct syndrome: re-connecting the duct

DOI: 10.17235/reed.2020.6650/2019

Imagen en Patología Digestiva

Intraductal papillary mucinous neoplasm of the biliary tract: a lesion of the bile duct lumen

DOI: 10.17235/reed.2019.6186/2019

Carta

Absceso hepático gigante por Fasciola hepatica

DOI: 10.17235/reed.2019.6136/2018

Imagen en Patología Digestiva

Cumbersome removal of an endoscopic nasobiliary drainage tube

DOI: 10.17235/reed.2019.5962/2018

Carta

A veces las cosas son lo que parecen

DOI: 10.17235/reed.2019.5911/2018

Imagen en Patología Digestiva

A rare case of acute obstructive suppurative pancreatic ductitis associated with ERCP

DOI: 10.17235/reed.2018.5756/2018

Carta al Editor

EUS-guided ethanol ablation therapy for gastric stromal tumors

DOI: 10.17235/reed.2017.5361/2017

Carta al Editor

Neoplasia neuroendocrina rectal

DOI: 10.17235/reed.2017.4836/2017

Revisión

Endoscopic ampullectomy: a technical review

DOI: 10.17235/reed.2016.3867/2015

Caso Clínico

Pelvic inflammatory myofibroblastic tumor mimicking a rectal cancer

DOI: 10.17235/reed.2015.3777/2015

Instrucciones para citar
Pérez-Cuadrado Robles E, Prat F, Deprez P. Endoscopic ultrasound-guided drainage with lumen-apposing metal stents: a good safety profile also in the long term?. 6348/2019


Descargar en un gestor de citas

Descargue la cita de este artículo haciendo clic en uno de los siguientes gestores de citas:

Métrica
Este artículo ha sido visitado 722 veces.
Este artículo ha sido descargado 175 veces.

Estadísticas de Dimensions


Estadísticas de Plum Analytics

Ficha Técnica

Recibido: 19/04/2019

Aceptado: 23/04/2019

Prepublicado: 13/05/2019

Publicado: 07/06/2019

Tiempo de prepublicación: 24 días

Tiempo de edición del artículo: 49 días


Compartir
Este artículo aun no tiene valoraciones.
Valoración del lector:
Valora este artículo:




Asociación Española de Ecografía Digestiva Sociedad Española de Endoscopia Digestiva Sociedad Española de Patología Digestiva
La REED es el órgano oficial de la Sociedad Española de Patología Digestiva, la SociedadEspañola de Endoscopia Digestiva y la Asociación Española de Ecografía Digestiva
Política de cookies Política de Privacidad Aviso Legal © Copyright 2023 y Creative Commons. Revista Española de Enfermedades Digestivas